Guides
Why the garage door won't close
If the door goes down a foot or two and then turns around, or won't start down at all, the safety sensors are the first place to look. In Houston, sunlight, debris and a slightly shifted slab cause a lot of those calls.

Check the photo-eye sensors
There is a small sensor on each side of the door, a few inches off the floor. They have to see each other. Wipe the lenses, move any broom, box, trash can or plant out of the path, and look at the lights: both should be steady, not blinking. If one is blinking, the beam is blocked or the brackets have been bumped. You can gently realign them so they point at each other; if they won't stay aligned, the bracket or the track may be bent.
Late-afternoon sun in a west-facing garage can wash out a sensor even when the lenses are clean. That's a common Houston complaint in summer. Shade the lens or slightly adjust the angle; if it keeps happening, we'll look at the sensor type and the mounting.
If the sensors look fine
The opener may be hitting a travel or force limit. That happens when the door is binding from dry rollers, a track that's no longer plumb, or a spring that's getting weak, and the opener thinks it has hit an obstruction. Don't turn the force all the way up to 'solve' it. That bypasses a safety feature. We'll find why the door is hard to move and then reset the limits.
A door that closes, touches the floor, and immediately opens again can also be a limit issue, or a sensor that only fails at a certain point in the travel. Clay soil that has shifted the slab is a regular reason tracks and sensors slowly drift in Houston.
When it's more than sensors
Crooked doors, scraped tracks and a door that jerks at one spot belong on the cable and off-track or opener repair pages. If you need the door closed and secured now, call for an emergency visit.
Common questions
Both sensor lights are on, but the door still reverses. Now what?
The beam may still be intermittent, or the opener's limits and force need to be set after we free up a binding door. That's an on-site adjustment, not something to guess at with the force dial.
Is it safe to close the door with the wall-button override?
Most openers will close if you hold the wall button, which bypasses the photo eyes. That is for clearing a known obstruction, not for everyday use, and it will not detect a person or pet in the opening. Fix the sensors.
The door started this after a heavy rain. Why?
Water and silt at the threshold, or a slab that moved, can block or shift the sensors. Dry and clean the lenses and the floor path first.
Door stuck? Start with a call.
Tell us what the door is doing and roughly where in Houston you are. If you would rather type it out, the estimate form goes to the same people.